CSE User's Manual

California Simulation Engine

4.39 DHWSOLARSYS

Solar water heating system.

May have any number of solar collectors, but only one tank.

May have no tank for direct system? What if system has multiple primary tanks?

swElecMtr=mtrName

Name of METER object, if any, to which DHWSOLARSYS electrical energy use is recorded (under end use ???).

UnitsLegal RangeDefaultRequiredVariability
oFname of a METERnot recordedNoconstant

swSCFluidSpHt=float

Specific heat for the collector fluid.

UnitsLegal RangeDefaultRequiredVariability
Btu/lbm-oFx \(>\) 00.9Noconstant

swSCFluidDens=float

Density for the collector fluid.

UnitsLegal RangeDefaultRequiredVariability
lb/ft3x \(>\) 064.0Noconstant

swEndUse

End use of pump energy; defaults to “DHW”.

swParElec=float

UnitsLegal RangeDefaultRequiredVariability
x \(\ge\) 00Nohourly

swTankHXEff=float

Tank heat exchanger effectiveness.

UnitsLegal RangeDefaultRequiredVariability
0 \(\le\) x \(\le\) 0.990Nohourly

swTankTHxLimit=float

Temperature limit for the tank collector.

UnitsLegal RangeDefaultRequiredVariability
oFx \(\geq\) 0180.0Noconstant

swTankUA=float

Heat transfer coefficient for the tank multiplied by area.

UnitsLegal RangeDefaultRequiredVariability
Btuh/oFNoconstant

swTankVol=float

UnitsLegal RangeDefaultRequiredVariability
galNoconstant

swTankInsulR=float

Total tank insulation resistance, built-in plus exterior wrap.

UnitsLegal RangeDefaultRequiredVariability
ft2-oF/BtuhNoconstant

swTankZone=znName

Pointer to tank zone location, use sw_tankTEx if NULL

UnitsLegal RangeDefaultRequiredVariability
Name of ZONENoconstant

swTankTEx=float

Surrounding temperature.

UnitsLegal RangeDefaultRequiredVariability
oFNohourly

endDHWSOLARSYS

Optionally indicates the end of the DHWSOLARSYS definition.

UnitsLegal RangeDefaultRequiredVariability
noneNo