4.40 DHWSOLARCOLLECTOR

Solar Collector Array. May be multiple collectors on the same DHWSOLARSYS system. All inlets come from the DHWSOLARTANK.

Uses SRCC Ratings.

scArea=float

Collector area.

UnitsLegal RangeDefaultRequiredVariability
ft^2\(>\) 00Yesconstant

scMult

Number of identical collectors, default 1

UnitsLegal RangeDefaultRequiredVariability
\(>\) 01Noconstant

scTilt=float

Array tilt.

UnitsLegal RangeDefaultRequiredVariability
deg0Yesconstant

scAzm=float

Array azimuth.

UnitsLegal RangeDefaultRequiredVariability
deg0Yesconstant

scFRUL=float

Fit slope

UnitsLegal RangeDefaultRequiredVariability
Btuh/ft2-o^F-0.727Noconstant

scFRTA=float

Fit y-intercept

UnitsLegal RangeDefaultRequiredVariability
none\(>\) 00.758Noconstant

scTestMassFlow=flaot

Mass flow rate for collector loop SRCC rating.

UnitsLegal RangeDefaultRequiredVariability
lb/h-ft2x \(>\) 014.79Noconstant

scKta60=float

Incident angle modifier at 60 degree, from SRCC rating.

UnitsLegal RangeDefaultRequiredVariability
x \(\geq\) 00.72Noconstant

scOprMassFlow=float

Collector loop operating mass flow rate.

UnitsLegal RangeDefaultRequiredVariability
lb/h-ft2x \(>\) 00.0Noconstant

scPipingLength=float

Collector piping length.

UnitsLegal RangeDefaultRequiredVariability
ftx \(\geq\) 00.0NoHourly and at the end of interval

scPipingInsulK=float

Collector piping insulation conductivity.

UnitsLegal RangeDefaultRequiredVariability
x \(>\) 00.02167NoHourly and at the end of interval

scPipingInsulThk=float

Collector piping insulation thickness.

UnitsLegal RangeDefaultRequiredVariability
x \(\geq\) 01.0NoHourly and at the end of interval

scPipingExH=float

Collector piping heat transfer coefficient.

UnitsLegal RangeDefaultRequiredVariability
x \(>\) 01.5NoHourly and at the end of interval

scPipingExT=float

Collector piping surround temperature.

UnitsLegal RangeDefaultRequiredVariability
oFx \(\geq\) 3270.0Nohourly

scPumpPwr=float

UnitsLegal RangeDefaultRequiredVariability
Btu/hx \(\ge\) 0from scPumpflowNoconstant

scPumpLiqHeatF=float

Fraction of scPumpPwr added to liquid stream, the remainder is discarded.

UnitsLegal RangeDefaultRequiredVariability
x \(\geq\) 01.0NoEvery run

scPumpOnDeltaT=float

Temperature difference between the tank and collector outlet where pump turns on

UnitsLegal RangeDefaultRequiredVariability
oF10.0Noconstant

scPumpOffDeltaT=float

Temperature difference between the tank and collector outlet where pump turns off

UnitsLegal RangeDefaultRequiredVariability
oF5.0Noconstant

endDHWSOLARCOLLECTOR

Optionally indicates the end of the DHWSOLARCOLLECTOR definition.

UnitsLegal RangeDefaultRequiredVariability
noneNo