CSE User's Manual

California Simulation Engine

4.41 DHWLOOPBRANCH

DHWLOOPBRANCH constructs one or more objects representing a branch pipe from the preceding DHWLOOPSEG. A DHWLOOPSEG can have any number of DHWLOOPBRANCHs to represent pipe runs with differing sizes, insulation, or surrounding conditions.

wbName

Optional name of segment; give after the word “DHWLOOPBRANCH” if desired.

UnitsLegal RangeDefaultRequiredVariability
63 charactersnoneNoconstant

wbMult=float

Specifies the number of identical DHWLOOPBRANCHs. Note may be non-integer.

UnitsLegal RangeDefaultRequiredVariability
x \(>\) 01Noconstant

wbLength=float

Length of branch.

UnitsLegal RangeDefaultRequiredVariability
ftx \(\ge\) 00Noconstant

wbSize=float

Nominal size of pipe. CSE assumes the pipe outside diameter = size + 0.125 in.

UnitsLegal RangeDefaultRequiredVariability
inx \(>\) 0noneYesconstant

wbInsulK=float

Pipe insulation conductivity

UnitsLegal RangeDefaultRequired**Variability
Btuh-ft/ft2-oFx \(>\) 00.02167Noconstant

wbInsulThk=float

Pipe insulation thickness

UnitsLegal RangeDefaultRequiredVariability
inx \(\ge\) 01Noconstant

wbExH=float

Combined radiant/convective exterior surface conductance between insulation (or pipe if no insulation) and surround.

UnitsLegal RangeDefaultRequiredVariability
Btuh/ft2-oFx \(>\) 01.5Nohourly

wbExCnd=choice

Specify exterior conditions.

ChoiceDescription
ADIABATICAdiabatic on other side
AMBIENTAmbient exterior
SPECTSpecify temperature
ADJZNAdjacent zone
GROUNDGround conditions
UnitsLegal RangeDefaultRequiredVariability
See table aboveSPECTNoconstant

wbAdjZn=float

Boundary conditions for adjacent zones.

UnitsLegal RangeDefaultRequiredVariability
x \(>\) 00.0Norunly

wbExTX=float

External boundary conditions.

UnitsLegal RangeDefaultRequiredVariability
x \(>\) 070.0Norunly

wbFUA=float

Adjustment factor applied to branch UA. UA is derived (from wbSize, wbLength, wbInsulK, wbInsulThk, and wbExH) and then multiplied by wbFUA. Used to represent e.g. imperfect insulation. Note that parent DHWLOOP wlFUA does not apply to DHWLOOPBRANCH (only DHWLOOPSEG)

UnitsLegal RangeDefaultRequiredVariability
x \(\ge\) 01Noconstant

wbExT=float

Surrounding equivalent temperature.

UnitsLegal RangeDefaultRequiredVariability
oFx \(>\) 070Nohourly

wbFlow=float

Branch flow rate assumed during draw.

UnitsLegal RangeDefaultRequiredVariability
gpmx \(\ge\) 02Nohourly

wbFWaste=float

Number of times during the hour when the branch volume is discarded.

UnitsLegal RangeDefaultRequiredVariability
x \(\ge\) 00Nohourly

endDHWLOOPBRANCH

Optionally indicates the end of the DHWLOOPBRANCH definition.

UnitsLegal RangeDefaultRequiredVariability
nonenoneNo

Related Probes: