CSE User's Manual

California Simulation Engine

4.39 DHWLOOPPUMP

DHWLOOPPUMP constructs an object representing a pump serving part a DHWLOOP. The model is identical to DHWPUMP except that that the electricity use calculation reflects wlRunF of the parent DHWLOOP.

wlpName

Optional name of pump; give after the word “DHWLOOPPUMP” if desired.

UnitsLegal RangeDefaultRequiredVariability
63 charactersnoneNoconstant

wlpMult=integer

Number of identical pumps of this type. Any value \(>1\) is equivalent to repeated entry of the same DHWPUMP.

UnitsLegal RangeDefaultRequiredVariability
x \(>\) 01Noconstant

wlpPwr=float

Pump power.

UnitsLegal RangeDefaultRequiredVariability
Wx \(>\) 00Nohourly

wlpLiqHeatF=float

Fraction of pump power that heats circulating liquid. The remainder is discarded.

UnitsLegal RangeDefaultRequiredVariability
0 \(\le\) x \(\le\) 11Nohourly

wlpElecMtr=mtrName

Name of METER object, if any, to which DHWLOOPPUMP electrical energy use is recorded (under end use dhwMFL).

UnitsLegal RangeDefaultRequiredVariability
name of a METERParent DHWLOOP wlElecMtrNoconstant

endDHWLOOPPUMP

Optionally indicates the end of the DHWPUMP definition.

UnitsLegal RangeDefaultRequiredVariability
noneNoconstant

Related Probes: