4.37 DHWPUMP
DHWPUMP constructs an object representing a domestic hot water circulation pump (or more than one if identical).
wpName
Optional name of pump; give after the word “DHWPUMP” if desired.
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
63 characters | none | No | constant |
wpMult=integer
Number of identical pumps of this type. Any value \(>1\) is equivalent to repeated entry of the same DHWPUMP.
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
x \(>\) 0 | 1 | No | constant |
wpPwr=float
Pump power.
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
W | x \(>\) 0 | 0 | No | hourly |
wpElecMtr=mtrName
Name of METER object, if any, to which DHWPUMP electrical energy use is recorded (under end use DHW).
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
name of a METER | Parent DHWSYS wsElecMtr | No | constant |
endDHWPump
Optionally indicates the end of the DHWPUMP definition.
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
none | No |
Related Probes: