6.7 construction
@construction[1..].
Name | Input? | Runtime? | Type | Variability | Description |
---|---|---|---|---|---|
name | X | – | string | constant | – |
conU | X | – | number | input time | U-value. entered by user or calculated from associated layers (lrs). 0 allowed. |
nLr | X | – | integer number | run start time (of each phase, autoSize or simulate) | 0 or number of layers (in lr rat). layers are entered in order from inside out. |
nFrmLr | X | – | integer number | run start time (of each phase, autoSize or simulate) | # framed layers: error if > 1; is-framed flag. |
r | X | – | number | run start time (of each phase, autoSize or simulate) | Thermal resistance of layers accumulated here for conu |
hc | X | – | number | run start time (of each phase, autoSize or simulate) | Accumulated heat capacity per square foot |
rNom | X | – | number | run start time (of each phase, autoSize or simulate) | Nominal r value |