RSYSRes

Name Type Variability Description/Comments
Y run results, aka year or annual
RSYSRES_IVL_SUB
Name Type Variability Description/Comments
Y.n number End of run
  • number of intervals added together in this one (divisor for averages)
  • (maintained but unused)
float members to add, hrsOn MUST be first (else change rsr_Accum() etc)
Name Type Variability Description/Comments
Y.hrsOn HOURS End of run operating hours
Y.hrsOnAux HOURS End of run
  • auxiliary heating operating hours (ASHP only)
  • does not include defrost
Name Type Variability Description/Comments
Y.qhPrimary ENERGY End of run heating output w/o fan, w/o defrost, Btu
Y.qhDefrost ENERGY End of run defrost (strip) heat output, Btu
Y.qhAux ENERGY End of run auxiliary heat output, Btu
Y.qhFan ENERGY End of run heating mode fan heat, Btu
Y.qhNet ENERGY End of run heating mode net output (qhPrimary+qhDefrost+qhAux+qhFan), Btu
Name Type Variability Description/Comments
Y.qcSen ENERGY End of run sensible cooling output w/o fan (< 0), Btu
Y.qcLat ENERGY End of run latent cooling output (<0), Btu
Y.qcFan ENERGY End of run cooling mode fan heat, Btu
Y.qcSenNet ENERGY End of run sensible cooling net output (qcSen+qcFan), Btu
Name Type Variability Description/Comments
Y.qvFan ENERGY End of run OAV mode fan heat, Btu
Name Type Variability Description/Comments
Y.fhPrimary ENERGY End of run heating mode primary fuel, Btu
Y.fhDefrost ENERGY End of run heating mode defrost fuel, Btu
Y.fhAux ENERGY End of run heating mode auxiliary fuel, Btu
Y.fhParasitic ENERGY End of run heating mode parasitic fuel, Btu
Y.fhTot ENERGY End of run
  • heating mode total fuel, Btu
  • primary+defrost+aux+parasitics
Name Type Variability Description/Comments
Y.ehPrimary ENERGY End of run
  • heating mode primary electicity use, Btu
  • (compressor, resistance, )
Y.ehDefrost ENERGY End of run heating mode defrost (strip) electricity use, Btu
Y.ehAux ENERGY End of run heating mode auxiliary (strip) electricity use, Btu
Y.ehFan ENERGY End of run heating mode fan electricity use, Btu
Y.ehParasitic ENERGY End of run heating mode parasitic electricity, Btu
Y.ehTot ENERGY End of run
  • heating mode total electricity use, Btu
  • primary+defrost+aux+fan+parasitic
Name Type Variability Description/Comments
Y.ecPrimary ENERGY End of run cooling mode compressor electricity use, Btu
Y.ecFan ENERGY End of run cooling mode fan electricity use, Btu
Y.ecParasitic ENERGY End of run cooling mode parasitic electricity, Btu
Y.ecTot ENERGY End of run
  • cooling mode total electricity use, Btu
  • primary+fan+parasitic
Name Type Variability Description/Comments
Y.evFan ENERGY End of run OAV mode fan electricity use, Btu
Y.evParasitic ENERGY End of run OAV mode parasitic electricity use, Btu
Y.evTot ENERGY End of run
  • OAV mode total electricity use, Btu
  • fan+parasistic
zone energy transfers (must be contiguous and in order, see code)
Name Type Variability Description/Comments
Y.qhZoneSen ENERGY End of run heating mode sensible transfer to zone(s) (after dist losses), Btu
Y.qhZoneLat ENERGY End of run heating mode latent transfer to zone(s) (after dist losses), Btu
Y.qcZoneSen ENERGY End of run cooling mode sensible transfer to zone(s) (after dist losses), Btu
Y.qcZoneLat ENERGY End of run cooling mode latent transfer to zone(s) (after dist losses), Btu
Y.qvZoneSen ENERGY End of run OAV mode sensible transfer to zone(s) (after dist losses), Btu
Y.qvZoneLat ENERGY End of run OAV mode latent transfer to zone(s) (after dist losses), Btu
M month
RSYSRES_IVL_SUB
Name Type Variability Description/Comments
M.n number Unknown
  • number of intervals added together in this one (divisor for averages)
  • (maintained but unused)
float members to add, hrsOn MUST be first (else change rsr_Accum() etc)
Name Type Variability Description/Comments
M.hrsOn HOURS Unknown operating hours
M.hrsOnAux HOURS Unknown
  • auxiliary heating operating hours (ASHP only)
  • does not include defrost
Name Type Variability Description/Comments
M.qhPrimary ENERGY Unknown heating output w/o fan, w/o defrost, Btu
M.qhDefrost ENERGY Unknown defrost (strip) heat output, Btu
M.qhAux ENERGY Unknown auxiliary heat output, Btu
M.qhFan ENERGY Unknown heating mode fan heat, Btu
M.qhNet ENERGY Unknown heating mode net output (qhPrimary+qhDefrost+qhAux+qhFan), Btu
Name Type Variability Description/Comments
M.qcSen ENERGY Unknown sensible cooling output w/o fan (< 0), Btu
M.qcLat ENERGY Unknown latent cooling output (<0), Btu
M.qcFan ENERGY Unknown cooling mode fan heat, Btu
M.qcSenNet ENERGY Unknown sensible cooling net output (qcSen+qcFan), Btu
Name Type Variability Description/Comments
M.qvFan ENERGY Unknown OAV mode fan heat, Btu
Name Type Variability Description/Comments
M.fhPrimary ENERGY Unknown heating mode primary fuel, Btu
M.fhDefrost ENERGY Unknown heating mode defrost fuel, Btu
M.fhAux ENERGY Unknown heating mode auxiliary fuel, Btu
M.fhParasitic ENERGY Unknown heating mode parasitic fuel, Btu
M.fhTot ENERGY Unknown
  • heating mode total fuel, Btu
  • primary+defrost+aux+parasitics
Name Type Variability Description/Comments
M.ehPrimary ENERGY Unknown
  • heating mode primary electicity use, Btu
  • (compressor, resistance, )
M.ehDefrost ENERGY Unknown heating mode defrost (strip) electricity use, Btu
M.ehAux ENERGY Unknown heating mode auxiliary (strip) electricity use, Btu
M.ehFan ENERGY Unknown heating mode fan electricity use, Btu
M.ehParasitic ENERGY Unknown heating mode parasitic electricity, Btu
M.ehTot ENERGY Unknown
  • heating mode total electricity use, Btu
  • primary+defrost+aux+fan+parasitic
Name Type Variability Description/Comments
M.ecPrimary ENERGY Unknown cooling mode compressor electricity use, Btu
M.ecFan ENERGY Unknown cooling mode fan electricity use, Btu
M.ecParasitic ENERGY Unknown cooling mode parasitic electricity, Btu
M.ecTot ENERGY Unknown
  • cooling mode total electricity use, Btu
  • primary+fan+parasitic
Name Type Variability Description/Comments
M.evFan ENERGY Unknown OAV mode fan electricity use, Btu
M.evParasitic ENERGY Unknown OAV mode parasitic electricity use, Btu
M.evTot ENERGY Unknown
  • OAV mode total electricity use, Btu
  • fan+parasistic
zone energy transfers (must be contiguous and in order, see code)
Name Type Variability Description/Comments
M.qhZoneSen ENERGY Unknown heating mode sensible transfer to zone(s) (after dist losses), Btu
M.qhZoneLat ENERGY Unknown heating mode latent transfer to zone(s) (after dist losses), Btu
M.qcZoneSen ENERGY Unknown cooling mode sensible transfer to zone(s) (after dist losses), Btu
M.qcZoneLat ENERGY Unknown cooling mode latent transfer to zone(s) (after dist losses), Btu
M.qvZoneSen ENERGY Unknown OAV mode sensible transfer to zone(s) (after dist losses), Btu
M.qvZoneLat ENERGY Unknown OAV mode latent transfer to zone(s) (after dist losses), Btu
D day
RSYSRES_IVL_SUB
Name Type Variability Description/Comments
D.n number End of day
  • number of intervals added together in this one (divisor for averages)
  • (maintained but unused)
float members to add, hrsOn MUST be first (else change rsr_Accum() etc)
Name Type Variability Description/Comments
D.hrsOn HOURS End of day operating hours
D.hrsOnAux HOURS End of day
  • auxiliary heating operating hours (ASHP only)
  • does not include defrost
Name Type Variability Description/Comments
D.qhPrimary ENERGY End of day heating output w/o fan, w/o defrost, Btu
D.qhDefrost ENERGY End of day defrost (strip) heat output, Btu
D.qhAux ENERGY End of day auxiliary heat output, Btu
D.qhFan ENERGY End of day heating mode fan heat, Btu
D.qhNet ENERGY End of day heating mode net output (qhPrimary+qhDefrost+qhAux+qhFan), Btu
Name Type Variability Description/Comments
D.qcSen ENERGY End of day sensible cooling output w/o fan (< 0), Btu
D.qcLat ENERGY End of day latent cooling output (<0), Btu
D.qcFan ENERGY End of day cooling mode fan heat, Btu
D.qcSenNet ENERGY End of day sensible cooling net output (qcSen+qcFan), Btu
Name Type Variability Description/Comments
D.qvFan ENERGY End of day OAV mode fan heat, Btu
Name Type Variability Description/Comments
D.fhPrimary ENERGY End of day heating mode primary fuel, Btu
D.fhDefrost ENERGY End of day heating mode defrost fuel, Btu
D.fhAux ENERGY End of day heating mode auxiliary fuel, Btu
D.fhParasitic ENERGY End of day heating mode parasitic fuel, Btu
D.fhTot ENERGY End of day
  • heating mode total fuel, Btu
  • primary+defrost+aux+parasitics
Name Type Variability Description/Comments
D.ehPrimary ENERGY End of day
  • heating mode primary electicity use, Btu
  • (compressor, resistance, )
D.ehDefrost ENERGY End of day heating mode defrost (strip) electricity use, Btu
D.ehAux ENERGY End of day heating mode auxiliary (strip) electricity use, Btu
D.ehFan ENERGY End of day heating mode fan electricity use, Btu
D.ehParasitic ENERGY End of day heating mode parasitic electricity, Btu
D.ehTot ENERGY End of day
  • heating mode total electricity use, Btu
  • primary+defrost+aux+fan+parasitic
Name Type Variability Description/Comments
D.ecPrimary ENERGY End of day cooling mode compressor electricity use, Btu
D.ecFan ENERGY End of day cooling mode fan electricity use, Btu
D.ecParasitic ENERGY End of day cooling mode parasitic electricity, Btu
D.ecTot ENERGY End of day
  • cooling mode total electricity use, Btu
  • primary+fan+parasitic
Name Type Variability Description/Comments
D.evFan ENERGY End of day OAV mode fan electricity use, Btu
D.evParasitic ENERGY End of day OAV mode parasitic electricity use, Btu
D.evTot ENERGY End of day
  • OAV mode total electricity use, Btu
  • fan+parasistic
zone energy transfers (must be contiguous and in order, see code)
Name Type Variability Description/Comments
D.qhZoneSen ENERGY End of day heating mode sensible transfer to zone(s) (after dist losses), Btu
D.qhZoneLat ENERGY End of day heating mode latent transfer to zone(s) (after dist losses), Btu
D.qcZoneSen ENERGY End of day cooling mode sensible transfer to zone(s) (after dist losses), Btu
D.qcZoneLat ENERGY End of day cooling mode latent transfer to zone(s) (after dist losses), Btu
D.qvZoneSen ENERGY End of day OAV mode sensible transfer to zone(s) (after dist losses), Btu
D.qvZoneLat ENERGY End of day OAV mode latent transfer to zone(s) (after dist losses), Btu
H hour.
RSYSRES_IVL_SUB
Name Type Variability Description/Comments
H.n number End of hour
  • number of intervals added together in this one (divisor for averages)
  • (maintained but unused)
float members to add, hrsOn MUST be first (else change rsr_Accum() etc)
Name Type Variability Description/Comments
H.hrsOn HOURS End of hour operating hours
H.hrsOnAux HOURS End of hour
  • auxiliary heating operating hours (ASHP only)
  • does not include defrost
Name Type Variability Description/Comments
H.qhPrimary ENERGY End of hour heating output w/o fan, w/o defrost, Btu
H.qhDefrost ENERGY End of hour defrost (strip) heat output, Btu
H.qhAux ENERGY End of hour auxiliary heat output, Btu
H.qhFan ENERGY End of hour heating mode fan heat, Btu
H.qhNet ENERGY End of hour heating mode net output (qhPrimary+qhDefrost+qhAux+qhFan), Btu
Name Type Variability Description/Comments
H.qcSen ENERGY End of hour sensible cooling output w/o fan (< 0), Btu
H.qcLat ENERGY End of hour latent cooling output (<0), Btu
H.qcFan ENERGY End of hour cooling mode fan heat, Btu
H.qcSenNet ENERGY End of hour sensible cooling net output (qcSen+qcFan), Btu
Name Type Variability Description/Comments
H.qvFan ENERGY End of hour OAV mode fan heat, Btu
Name Type Variability Description/Comments
H.fhPrimary ENERGY End of hour heating mode primary fuel, Btu
H.fhDefrost ENERGY End of hour heating mode defrost fuel, Btu
H.fhAux ENERGY End of hour heating mode auxiliary fuel, Btu
H.fhParasitic ENERGY End of hour heating mode parasitic fuel, Btu
H.fhTot ENERGY End of hour
  • heating mode total fuel, Btu
  • primary+defrost+aux+parasitics
Name Type Variability Description/Comments
H.ehPrimary ENERGY End of hour
  • heating mode primary electicity use, Btu
  • (compressor, resistance, )
H.ehDefrost ENERGY End of hour heating mode defrost (strip) electricity use, Btu
H.ehAux ENERGY End of hour heating mode auxiliary (strip) electricity use, Btu
H.ehFan ENERGY End of hour heating mode fan electricity use, Btu
H.ehParasitic ENERGY End of hour heating mode parasitic electricity, Btu
H.ehTot ENERGY End of hour
  • heating mode total electricity use, Btu
  • primary+defrost+aux+fan+parasitic
Name Type Variability Description/Comments
H.ecPrimary ENERGY End of hour cooling mode compressor electricity use, Btu
H.ecFan ENERGY End of hour cooling mode fan electricity use, Btu
H.ecParasitic ENERGY End of hour cooling mode parasitic electricity, Btu
H.ecTot ENERGY End of hour
  • cooling mode total electricity use, Btu
  • primary+fan+parasitic
Name Type Variability Description/Comments
H.evFan ENERGY End of hour OAV mode fan electricity use, Btu
H.evParasitic ENERGY End of hour OAV mode parasitic electricity use, Btu
H.evTot ENERGY End of hour
  • OAV mode total electricity use, Btu
  • fan+parasistic
zone energy transfers (must be contiguous and in order, see code)
Name Type Variability Description/Comments
H.qhZoneSen ENERGY End of hour heating mode sensible transfer to zone(s) (after dist losses), Btu
H.qhZoneLat ENERGY End of hour heating mode latent transfer to zone(s) (after dist losses), Btu
H.qcZoneSen ENERGY End of hour cooling mode sensible transfer to zone(s) (after dist losses), Btu
H.qcZoneLat ENERGY End of hour cooling mode latent transfer to zone(s) (after dist losses), Btu
H.qvZoneSen ENERGY End of hour OAV mode sensible transfer to zone(s) (after dist losses), Btu
H.qvZoneLat ENERGY End of hour OAV mode latent transfer to zone(s) (after dist losses), Btu
S subhour, aka subStep or sub-time-step
RSYSRES_IVL_SUB
Name Type Variability Description/Comments
S.n number End of subhour
  • number of intervals added together in this one (divisor for averages)
  • (maintained but unused)
float members to add, hrsOn MUST be first (else change rsr_Accum() etc)
Name Type Variability Description/Comments
S.hrsOn HOURS End of subhour operating hours
S.hrsOnAux HOURS End of subhour
  • auxiliary heating operating hours (ASHP only)
  • does not include defrost
Name Type Variability Description/Comments
S.qhPrimary ENERGY End of subhour heating output w/o fan, w/o defrost, Btu
S.qhDefrost ENERGY End of subhour defrost (strip) heat output, Btu
S.qhAux ENERGY End of subhour auxiliary heat output, Btu
S.qhFan ENERGY End of subhour heating mode fan heat, Btu
S.qhNet ENERGY End of subhour heating mode net output (qhPrimary+qhDefrost+qhAux+qhFan), Btu
Name Type Variability Description/Comments
S.qcSen ENERGY End of subhour sensible cooling output w/o fan (< 0), Btu
S.qcLat ENERGY End of subhour latent cooling output (<0), Btu
S.qcFan ENERGY End of subhour cooling mode fan heat, Btu
S.qcSenNet ENERGY End of subhour sensible cooling net output (qcSen+qcFan), Btu
Name Type Variability Description/Comments
S.qvFan ENERGY End of subhour OAV mode fan heat, Btu
Name Type Variability Description/Comments
S.fhPrimary ENERGY End of subhour heating mode primary fuel, Btu
S.fhDefrost ENERGY End of subhour heating mode defrost fuel, Btu
S.fhAux ENERGY End of subhour heating mode auxiliary fuel, Btu
S.fhParasitic ENERGY End of subhour heating mode parasitic fuel, Btu
S.fhTot ENERGY End of subhour
  • heating mode total fuel, Btu
  • primary+defrost+aux+parasitics
Name Type Variability Description/Comments
S.ehPrimary ENERGY End of subhour
  • heating mode primary electicity use, Btu
  • (compressor, resistance, )
S.ehDefrost ENERGY End of subhour heating mode defrost (strip) electricity use, Btu
S.ehAux ENERGY End of subhour heating mode auxiliary (strip) electricity use, Btu
S.ehFan ENERGY End of subhour heating mode fan electricity use, Btu
S.ehParasitic ENERGY End of subhour heating mode parasitic electricity, Btu
S.ehTot ENERGY End of subhour
  • heating mode total electricity use, Btu
  • primary+defrost+aux+fan+parasitic
Name Type Variability Description/Comments
S.ecPrimary ENERGY End of subhour cooling mode compressor electricity use, Btu
S.ecFan ENERGY End of subhour cooling mode fan electricity use, Btu
S.ecParasitic ENERGY End of subhour cooling mode parasitic electricity, Btu
S.ecTot ENERGY End of subhour
  • cooling mode total electricity use, Btu
  • primary+fan+parasitic
Name Type Variability Description/Comments
S.evFan ENERGY End of subhour OAV mode fan electricity use, Btu
S.evParasitic ENERGY End of subhour OAV mode parasitic electricity use, Btu
S.evTot ENERGY End of subhour
  • OAV mode total electricity use, Btu
  • fan+parasistic
zone energy transfers (must be contiguous and in order, see code)
Name Type Variability Description/Comments
S.qhZoneSen ENERGY End of subhour heating mode sensible transfer to zone(s) (after dist losses), Btu
S.qhZoneLat ENERGY End of subhour heating mode latent transfer to zone(s) (after dist losses), Btu
S.qcZoneSen ENERGY End of subhour cooling mode sensible transfer to zone(s) (after dist losses), Btu
S.qcZoneLat ENERGY End of subhour cooling mode latent transfer to zone(s) (after dist losses), Btu
S.qvZoneSen ENERGY End of subhour OAV mode sensible transfer to zone(s) (after dist losses), Btu
S.qvZoneLat ENERGY End of subhour OAV mode latent transfer to zone(s) (after dist losses), Btu
Name Type Variability Description/Comments
prior
  • prior year,month,day,hour,subhr results, available throughout interval
  • CAUTION: code assumes prior and curr arranged so can offset from curr to prior. eg in cnguts.cpp.
RSYSRES_SUB
Name Type Variability Description/Comments
prior.Y run results, aka year or annual
RSYSRES_IVL_SUB
Name Type Variability Description/Comments
prior.Y.n number Start of run
  • number of intervals added together in this one (divisor for averages)
  • (maintained but unused)
float members to add, hrsOn MUST be first (else change rsr_Accum() etc)
Name Type Variability Description/Comments
prior.Y.hrsOn HOURS Start of run operating hours
prior.Y.hrsOnAux HOURS Start of run
  • auxiliary heating operating hours (ASHP only)
  • does not include defrost
Name Type Variability Description/Comments
prior.Y.qhPrimary ENERGY Start of run heating output w/o fan, w/o defrost, Btu
prior.Y.qhDefrost ENERGY Start of run defrost (strip) heat output, Btu
prior.Y.qhAux ENERGY Start of run auxiliary heat output, Btu
prior.Y.qhFan ENERGY Start of run heating mode fan heat, Btu
prior.Y.qhNet ENERGY Start of run heating mode net output (qhPrimary+qhDefrost+qhAux+qhFan), Btu
Name Type Variability Description/Comments
prior.Y.qcSen ENERGY Start of run sensible cooling output w/o fan (< 0), Btu
prior.Y.qcLat ENERGY Start of run latent cooling output (<0), Btu
prior.Y.qcFan ENERGY Start of run cooling mode fan heat, Btu
prior.Y.qcSenNet ENERGY Start of run sensible cooling net output (qcSen+qcFan), Btu
Name Type Variability Description/Comments
prior.Y.qvFan ENERGY Start of run OAV mode fan heat, Btu
Name Type Variability Description/Comments
prior.Y.fhPrimary ENERGY Start of run heating mode primary fuel, Btu
prior.Y.fhDefrost ENERGY Start of run heating mode defrost fuel, Btu
prior.Y.fhAux ENERGY Start of run heating mode auxiliary fuel, Btu
prior.Y.fhParasitic ENERGY Start of run heating mode parasitic fuel, Btu
prior.Y.fhTot ENERGY Start of run
  • heating mode total fuel, Btu
  • primary+defrost+aux+parasitics
Name Type Variability Description/Comments
prior.Y.ehPrimary ENERGY Start of run
  • heating mode primary electicity use, Btu
  • (compressor, resistance, )
prior.Y.ehDefrost ENERGY Start of run heating mode defrost (strip) electricity use, Btu
prior.Y.ehAux ENERGY Start of run heating mode auxiliary (strip) electricity use, Btu
prior.Y.ehFan ENERGY Start of run heating mode fan electricity use, Btu
prior.Y.ehParasitic ENERGY Start of run heating mode parasitic electricity, Btu
prior.Y.ehTot ENERGY Start of run
  • heating mode total electricity use, Btu
  • primary+defrost+aux+fan+parasitic
Name Type Variability Description/Comments
prior.Y.ecPrimary ENERGY Start of run cooling mode compressor electricity use, Btu
prior.Y.ecFan ENERGY Start of run cooling mode fan electricity use, Btu
prior.Y.ecParasitic ENERGY Start of run cooling mode parasitic electricity, Btu
prior.Y.ecTot ENERGY Start of run
  • cooling mode total electricity use, Btu
  • primary+fan+parasitic
Name Type Variability Description/Comments
prior.Y.evFan ENERGY Start of run OAV mode fan electricity use, Btu
prior.Y.evParasitic ENERGY Start of run OAV mode parasitic electricity use, Btu
prior.Y.evTot ENERGY Start of run
  • OAV mode total electricity use, Btu
  • fan+parasistic
zone energy transfers (must be contiguous and in order, see code)
Name Type Variability Description/Comments
prior.Y.qhZoneSen ENERGY Start of run heating mode sensible transfer to zone(s) (after dist losses), Btu
prior.Y.qhZoneLat ENERGY Start of run heating mode latent transfer to zone(s) (after dist losses), Btu
prior.Y.qcZoneSen ENERGY Start of run cooling mode sensible transfer to zone(s) (after dist losses), Btu
prior.Y.qcZoneLat ENERGY Start of run cooling mode latent transfer to zone(s) (after dist losses), Btu
prior.Y.qvZoneSen ENERGY Start of run OAV mode sensible transfer to zone(s) (after dist losses), Btu
prior.Y.qvZoneLat ENERGY Start of run OAV mode latent transfer to zone(s) (after dist losses), Btu
prior.M month
RSYSRES_IVL_SUB
Name Type Variability Description/Comments
prior.M.n number Unknown
  • number of intervals added together in this one (divisor for averages)
  • (maintained but unused)
float members to add, hrsOn MUST be first (else change rsr_Accum() etc)
Name Type Variability Description/Comments
prior.M.hrsOn HOURS Unknown operating hours
prior.M.hrsOnAux HOURS Unknown
  • auxiliary heating operating hours (ASHP only)
  • does not include defrost
Name Type Variability Description/Comments
prior.M.qhPrimary ENERGY Unknown heating output w/o fan, w/o defrost, Btu
prior.M.qhDefrost ENERGY Unknown defrost (strip) heat output, Btu
prior.M.qhAux ENERGY Unknown auxiliary heat output, Btu
prior.M.qhFan ENERGY Unknown heating mode fan heat, Btu
prior.M.qhNet ENERGY Unknown heating mode net output (qhPrimary+qhDefrost+qhAux+qhFan), Btu
Name Type Variability Description/Comments
prior.M.qcSen ENERGY Unknown sensible cooling output w/o fan (< 0), Btu
prior.M.qcLat ENERGY Unknown latent cooling output (<0), Btu
prior.M.qcFan ENERGY Unknown cooling mode fan heat, Btu
prior.M.qcSenNet ENERGY Unknown sensible cooling net output (qcSen+qcFan), Btu
Name Type Variability Description/Comments
prior.M.qvFan ENERGY Unknown OAV mode fan heat, Btu
Name Type Variability Description/Comments
prior.M.fhPrimary ENERGY Unknown heating mode primary fuel, Btu
prior.M.fhDefrost ENERGY Unknown heating mode defrost fuel, Btu
prior.M.fhAux ENERGY Unknown heating mode auxiliary fuel, Btu
prior.M.fhParasitic ENERGY Unknown heating mode parasitic fuel, Btu
prior.M.fhTot ENERGY Unknown
  • heating mode total fuel, Btu
  • primary+defrost+aux+parasitics
Name Type Variability Description/Comments
prior.M.ehPrimary ENERGY Unknown
  • heating mode primary electicity use, Btu
  • (compressor, resistance, )
prior.M.ehDefrost ENERGY Unknown heating mode defrost (strip) electricity use, Btu
prior.M.ehAux ENERGY Unknown heating mode auxiliary (strip) electricity use, Btu
prior.M.ehFan ENERGY Unknown heating mode fan electricity use, Btu
prior.M.ehParasitic ENERGY Unknown heating mode parasitic electricity, Btu
prior.M.ehTot ENERGY Unknown
  • heating mode total electricity use, Btu
  • primary+defrost+aux+fan+parasitic
Name Type Variability Description/Comments
prior.M.ecPrimary ENERGY Unknown cooling mode compressor electricity use, Btu
prior.M.ecFan ENERGY Unknown cooling mode fan electricity use, Btu
prior.M.ecParasitic ENERGY Unknown cooling mode parasitic electricity, Btu
prior.M.ecTot ENERGY Unknown
  • cooling mode total electricity use, Btu
  • primary+fan+parasitic
Name Type Variability Description/Comments
prior.M.evFan ENERGY Unknown OAV mode fan electricity use, Btu
prior.M.evParasitic ENERGY Unknown OAV mode parasitic electricity use, Btu
prior.M.evTot ENERGY Unknown
  • OAV mode total electricity use, Btu
  • fan+parasistic
zone energy transfers (must be contiguous and in order, see code)
Name Type Variability Description/Comments
prior.M.qhZoneSen ENERGY Unknown heating mode sensible transfer to zone(s) (after dist losses), Btu
prior.M.qhZoneLat ENERGY Unknown heating mode latent transfer to zone(s) (after dist losses), Btu
prior.M.qcZoneSen ENERGY Unknown cooling mode sensible transfer to zone(s) (after dist losses), Btu
prior.M.qcZoneLat ENERGY Unknown cooling mode latent transfer to zone(s) (after dist losses), Btu
prior.M.qvZoneSen ENERGY Unknown OAV mode sensible transfer to zone(s) (after dist losses), Btu
prior.M.qvZoneLat ENERGY Unknown OAV mode latent transfer to zone(s) (after dist losses), Btu
prior.D day
RSYSRES_IVL_SUB
Name Type Variability Description/Comments
prior.D.n number Start of day
  • number of intervals added together in this one (divisor for averages)
  • (maintained but unused)
float members to add, hrsOn MUST be first (else change rsr_Accum() etc)
Name Type Variability Description/Comments
prior.D.hrsOn HOURS Start of day operating hours
prior.D.hrsOnAux HOURS Start of day
  • auxiliary heating operating hours (ASHP only)
  • does not include defrost
Name Type Variability Description/Comments
prior.D.qhPrimary ENERGY Start of day heating output w/o fan, w/o defrost, Btu
prior.D.qhDefrost ENERGY Start of day defrost (strip) heat output, Btu
prior.D.qhAux ENERGY Start of day auxiliary heat output, Btu
prior.D.qhFan ENERGY Start of day heating mode fan heat, Btu
prior.D.qhNet ENERGY Start of day heating mode net output (qhPrimary+qhDefrost+qhAux+qhFan), Btu
Name Type Variability Description/Comments
prior.D.qcSen ENERGY Start of day sensible cooling output w/o fan (< 0), Btu
prior.D.qcLat ENERGY Start of day latent cooling output (<0), Btu
prior.D.qcFan ENERGY Start of day cooling mode fan heat, Btu
prior.D.qcSenNet ENERGY Start of day sensible cooling net output (qcSen+qcFan), Btu
Name Type Variability Description/Comments
prior.D.qvFan ENERGY Start of day OAV mode fan heat, Btu
Name Type Variability Description/Comments
prior.D.fhPrimary ENERGY Start of day heating mode primary fuel, Btu
prior.D.fhDefrost ENERGY Start of day heating mode defrost fuel, Btu
prior.D.fhAux ENERGY Start of day heating mode auxiliary fuel, Btu
prior.D.fhParasitic ENERGY Start of day heating mode parasitic fuel, Btu
prior.D.fhTot ENERGY Start of day
  • heating mode total fuel, Btu
  • primary+defrost+aux+parasitics
Name Type Variability Description/Comments
prior.D.ehPrimary ENERGY Start of day
  • heating mode primary electicity use, Btu
  • (compressor, resistance, )
prior.D.ehDefrost ENERGY Start of day heating mode defrost (strip) electricity use, Btu
prior.D.ehAux ENERGY Start of day heating mode auxiliary (strip) electricity use, Btu
prior.D.ehFan ENERGY Start of day heating mode fan electricity use, Btu
prior.D.ehParasitic ENERGY Start of day heating mode parasitic electricity, Btu
prior.D.ehTot ENERGY Start of day
  • heating mode total electricity use, Btu
  • primary+defrost+aux+fan+parasitic
Name Type Variability Description/Comments
prior.D.ecPrimary ENERGY Start of day cooling mode compressor electricity use, Btu
prior.D.ecFan ENERGY Start of day cooling mode fan electricity use, Btu
prior.D.ecParasitic ENERGY Start of day cooling mode parasitic electricity, Btu
prior.D.ecTot ENERGY Start of day
  • cooling mode total electricity use, Btu
  • primary+fan+parasitic
Name Type Variability Description/Comments
prior.D.evFan ENERGY Start of day OAV mode fan electricity use, Btu
prior.D.evParasitic ENERGY Start of day OAV mode parasitic electricity use, Btu
prior.D.evTot ENERGY Start of day
  • OAV mode total electricity use, Btu
  • fan+parasistic
zone energy transfers (must be contiguous and in order, see code)
Name Type Variability Description/Comments
prior.D.qhZoneSen ENERGY Start of day heating mode sensible transfer to zone(s) (after dist losses), Btu
prior.D.qhZoneLat ENERGY Start of day heating mode latent transfer to zone(s) (after dist losses), Btu
prior.D.qcZoneSen ENERGY Start of day cooling mode sensible transfer to zone(s) (after dist losses), Btu
prior.D.qcZoneLat ENERGY Start of day cooling mode latent transfer to zone(s) (after dist losses), Btu
prior.D.qvZoneSen ENERGY Start of day OAV mode sensible transfer to zone(s) (after dist losses), Btu
prior.D.qvZoneLat ENERGY Start of day OAV mode latent transfer to zone(s) (after dist losses), Btu
prior.H hour.
RSYSRES_IVL_SUB
Name Type Variability Description/Comments
prior.H.n number Start of hour
  • number of intervals added together in this one (divisor for averages)
  • (maintained but unused)
float members to add, hrsOn MUST be first (else change rsr_Accum() etc)
Name Type Variability Description/Comments
prior.H.hrsOn HOURS Start of hour operating hours
prior.H.hrsOnAux HOURS Start of hour
  • auxiliary heating operating hours (ASHP only)
  • does not include defrost
Name Type Variability Description/Comments
prior.H.qhPrimary ENERGY Start of hour heating output w/o fan, w/o defrost, Btu
prior.H.qhDefrost ENERGY Start of hour defrost (strip) heat output, Btu
prior.H.qhAux ENERGY Start of hour auxiliary heat output, Btu
prior.H.qhFan ENERGY Start of hour heating mode fan heat, Btu
prior.H.qhNet ENERGY Start of hour heating mode net output (qhPrimary+qhDefrost+qhAux+qhFan), Btu
Name Type Variability Description/Comments
prior.H.qcSen ENERGY Start of hour sensible cooling output w/o fan (< 0), Btu
prior.H.qcLat ENERGY Start of hour latent cooling output (<0), Btu
prior.H.qcFan ENERGY Start of hour cooling mode fan heat, Btu
prior.H.qcSenNet ENERGY Start of hour sensible cooling net output (qcSen+qcFan), Btu
Name Type Variability Description/Comments
prior.H.qvFan ENERGY Start of hour OAV mode fan heat, Btu
Name Type Variability Description/Comments
prior.H.fhPrimary ENERGY Start of hour heating mode primary fuel, Btu
prior.H.fhDefrost ENERGY Start of hour heating mode defrost fuel, Btu
prior.H.fhAux ENERGY Start of hour heating mode auxiliary fuel, Btu
prior.H.fhParasitic ENERGY Start of hour heating mode parasitic fuel, Btu
prior.H.fhTot ENERGY Start of hour
  • heating mode total fuel, Btu
  • primary+defrost+aux+parasitics
Name Type Variability Description/Comments
prior.H.ehPrimary ENERGY Start of hour
  • heating mode primary electicity use, Btu
  • (compressor, resistance, )
prior.H.ehDefrost ENERGY Start of hour heating mode defrost (strip) electricity use, Btu
prior.H.ehAux ENERGY Start of hour heating mode auxiliary (strip) electricity use, Btu
prior.H.ehFan ENERGY Start of hour heating mode fan electricity use, Btu
prior.H.ehParasitic ENERGY Start of hour heating mode parasitic electricity, Btu
prior.H.ehTot ENERGY Start of hour
  • heating mode total electricity use, Btu
  • primary+defrost+aux+fan+parasitic
Name Type Variability Description/Comments
prior.H.ecPrimary ENERGY Start of hour cooling mode compressor electricity use, Btu
prior.H.ecFan ENERGY Start of hour cooling mode fan electricity use, Btu
prior.H.ecParasitic ENERGY Start of hour cooling mode parasitic electricity, Btu
prior.H.ecTot ENERGY Start of hour
  • cooling mode total electricity use, Btu
  • primary+fan+parasitic
Name Type Variability Description/Comments
prior.H.evFan ENERGY Start of hour OAV mode fan electricity use, Btu
prior.H.evParasitic ENERGY Start of hour OAV mode parasitic electricity use, Btu
prior.H.evTot ENERGY Start of hour
  • OAV mode total electricity use, Btu
  • fan+parasistic
zone energy transfers (must be contiguous and in order, see code)
Name Type Variability Description/Comments
prior.H.qhZoneSen ENERGY Start of hour heating mode sensible transfer to zone(s) (after dist losses), Btu
prior.H.qhZoneLat ENERGY Start of hour heating mode latent transfer to zone(s) (after dist losses), Btu
prior.H.qcZoneSen ENERGY Start of hour cooling mode sensible transfer to zone(s) (after dist losses), Btu
prior.H.qcZoneLat ENERGY Start of hour cooling mode latent transfer to zone(s) (after dist losses), Btu
prior.H.qvZoneSen ENERGY Start of hour OAV mode sensible transfer to zone(s) (after dist losses), Btu
prior.H.qvZoneLat ENERGY Start of hour OAV mode latent transfer to zone(s) (after dist losses), Btu
prior.S subhour, aka subStep or sub-time-step
RSYSRES_IVL_SUB
Name Type Variability Description/Comments
prior.S.n number Start of subhour
  • number of intervals added together in this one (divisor for averages)
  • (maintained but unused)
float members to add, hrsOn MUST be first (else change rsr_Accum() etc)
Name Type Variability Description/Comments
prior.S.hrsOn HOURS Start of subhour operating hours
prior.S.hrsOnAux HOURS Start of subhour
  • auxiliary heating operating hours (ASHP only)
  • does not include defrost
Name Type Variability Description/Comments
prior.S.qhPrimary ENERGY Start of subhour heating output w/o fan, w/o defrost, Btu
prior.S.qhDefrost ENERGY Start of subhour defrost (strip) heat output, Btu
prior.S.qhAux ENERGY Start of subhour auxiliary heat output, Btu
prior.S.qhFan ENERGY Start of subhour heating mode fan heat, Btu
prior.S.qhNet ENERGY Start of subhour heating mode net output (qhPrimary+qhDefrost+qhAux+qhFan), Btu
Name Type Variability Description/Comments
prior.S.qcSen ENERGY Start of subhour sensible cooling output w/o fan (< 0), Btu
prior.S.qcLat ENERGY Start of subhour latent cooling output (<0), Btu
prior.S.qcFan ENERGY Start of subhour cooling mode fan heat, Btu
prior.S.qcSenNet ENERGY Start of subhour sensible cooling net output (qcSen+qcFan), Btu
Name Type Variability Description/Comments
prior.S.qvFan ENERGY Start of subhour OAV mode fan heat, Btu
Name Type Variability Description/Comments
prior.S.fhPrimary ENERGY Start of subhour heating mode primary fuel, Btu
prior.S.fhDefrost ENERGY Start of subhour heating mode defrost fuel, Btu
prior.S.fhAux ENERGY Start of subhour heating mode auxiliary fuel, Btu
prior.S.fhParasitic ENERGY Start of subhour heating mode parasitic fuel, Btu
prior.S.fhTot ENERGY Start of subhour
  • heating mode total fuel, Btu
  • primary+defrost+aux+parasitics
Name Type Variability Description/Comments
prior.S.ehPrimary ENERGY Start of subhour
  • heating mode primary electicity use, Btu
  • (compressor, resistance, )
prior.S.ehDefrost ENERGY Start of subhour heating mode defrost (strip) electricity use, Btu
prior.S.ehAux ENERGY Start of subhour heating mode auxiliary (strip) electricity use, Btu
prior.S.ehFan ENERGY Start of subhour heating mode fan electricity use, Btu
prior.S.ehParasitic ENERGY Start of subhour heating mode parasitic electricity, Btu
prior.S.ehTot ENERGY Start of subhour
  • heating mode total electricity use, Btu
  • primary+defrost+aux+fan+parasitic
Name Type Variability Description/Comments
prior.S.ecPrimary ENERGY Start of subhour cooling mode compressor electricity use, Btu
prior.S.ecFan ENERGY Start of subhour cooling mode fan electricity use, Btu
prior.S.ecParasitic ENERGY Start of subhour cooling mode parasitic electricity, Btu
prior.S.ecTot ENERGY Start of subhour
  • cooling mode total electricity use, Btu
  • primary+fan+parasitic
Name Type Variability Description/Comments
prior.S.evFan ENERGY Start of subhour OAV mode fan electricity use, Btu
prior.S.evParasitic ENERGY Start of subhour OAV mode parasitic electricity use, Btu
prior.S.evTot ENERGY Start of subhour
  • OAV mode total electricity use, Btu
  • fan+parasistic
zone energy transfers (must be contiguous and in order, see code)
Name Type Variability Description/Comments
prior.S.qhZoneSen ENERGY Start of subhour heating mode sensible transfer to zone(s) (after dist losses), Btu
prior.S.qhZoneLat ENERGY Start of subhour heating mode latent transfer to zone(s) (after dist losses), Btu
prior.S.qcZoneSen ENERGY Start of subhour cooling mode sensible transfer to zone(s) (after dist losses), Btu
prior.S.qcZoneLat ENERGY Start of subhour cooling mode latent transfer to zone(s) (after dist losses), Btu
prior.S.qvZoneSen ENERGY Start of subhour OAV mode sensible transfer to zone(s) (after dist losses), Btu
prior.S.qvZoneLat ENERGY Start of subhour OAV mode latent transfer to zone(s) (after dist losses), Btu