DHWSOLARSYS

Solar water heating system.

  • DHWSOLARSYS
    • DHWSOLARCOLLECTOR
    • DHWSOLARTANK

May have any number of solar collectors, but only one tank.

May have no tank for direct system? What if system has multiple primary tanks?

swElecMtr

Type: mtrName

Name of METER object, if any, to which DHWSOLARSYS electrical energy use is recorded (under end use ???).

Units Legal Range Default Required Variability
oF name of a METER not recorded No constant

swSCFluidSpHt

Type: float

Specific heat for the collector fluid.

Units Legal Range Default Required Variability
Btu/lbm-oF x \(>\) 0 0.9 No constant

swSCFluidDens

Type: float

Density for the collector fluid.

Units Legal Range Default Required Variability
lb/ft3 x \(>\) 0 64.0 No constant

swEndUse

End use of pump energy; defaults to "DHW".

swParElec

Type: float

Units Legal Range Default Required Variability
x \(\ge\) 0 0 No hourly

swTankHXEff

Type: float

Tank heat exchanger effectiveness.

Units Legal Range Default Required Variability
0 \(\le\) x \(\le\) 0.99 0 No hourly

swTankTHxLimit

Type: float

Temperature limit for the tank collector.

Units Legal Range Default Required Variability
oF x \(\geq\) 0 180.0 No constant

swTankUA

Type: float

Heat transfer coefficient for the tank multiplied by area.

Units Legal Range Default Required Variability
Btuh/oF No constant

swTankVol

Type: float

Units Legal Range Default Required Variability
gal No constant

swTankInsulR

Type: float

Total tank insulation resistance, built-in plus exterior wrap.

Units Legal Range Default Required Variability
ft2-oF/Btuh No constant

swTankZone

Type: znName

Pointer to tank zone location, use sw_tankTEx if NULL

Units Legal Range Default Required Variability
Name of ZONE No constant

swTankTEx

Type: float

Surrounding temperature.

Units Legal Range Default Required Variability
oF No hourly

endDHWSOLARSYS

Optionally indicates the end of the DHWSOLARSYS definition.

Units Legal Range Default Required Variability
none No