DHWSOLARSYS¶
Solar water heating system.
- DHWSOLARSYS
- DHWSOLARCOLLECTOR
- DHWSOLARTANK
May have any number of solar collectors, but only one tank.
May have no tank for direct system? What if system has multiple primary tanks?
swElecMtr¶
Type: mtrName
Name of METER object, if any, to which DHWSOLARSYS electrical energy use is recorded (under end use ???).
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
°F | name of a METER | not recorded | No | constant |
swSCFluidSpHt¶
Type: float
Specific heat for the collector fluid.
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
Btu/lbm-°F | x > 0 | 0.9 | No | constant |
swSCFluidDens¶
Type: float
Density for the collector fluid.
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
lb/ft3 | x > 0 | 64.0 | No | constant |
swEndUse¶
End use of pump energy; defaults to "DHW".
swParElec¶
Type: float
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
x ≥ 0 | 0 | No | hourly |
swTankHXEff¶
Type: float
Tank heat exchanger effectiveness.
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
0 ≤ x ≤ 0.99 | 0 | No | hourly |
swTankTHxLimit¶
Type: float
Temperature limit for the tank collector.
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
°F | x ≥ 0 | 180.0 | No | constant |
swTankUA¶
Type: float
Heat transfer coefficient for the tank multiplied by area.
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
Btuh/°F | No | constant |
swTankVol¶
Type: float
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
gal | No | constant |
swTankInsulR¶
Type: float
Total tank insulation resistance, built-in plus exterior wrap.
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
ft2-°F/Btuh | No | constant |
swTankZone¶
Type: znName
Pointer to tank zone location, use sw_tankTEx if NULL
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
Name of ZONE | No | constant |
swTankTEx¶
Type: float
Surrounding temperature.
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
°F | No | hourly |
endDHWSOLARSYS¶
Optionally indicates the end of the DHWSOLARSYS definition.
Units | Legal Range | Default | Required | Variability |
---|---|---|---|---|
none | No |