DHWLOOPSEG

DHWLOOPSEG constructs one or more objects representing a segment of the preceeding DHWLOOP. A DHWLOOP can have any number of DHWLOOPSEGs to represent the segments of the loop with possibly differing sizes, insulation, or surrounding conditions.

wgName

Optional name of segment; give after the word “DHWLOOPSEG” if desired.

Units Legal Range Default Required Variability
63 characters none No constant

wgTy

Type: choice

Specifies the type of segment. RETURN segments, if any, must follow SUPPLY segments.

SUPPLY Indicates a supply segment (flow is sum of circulation and draw flow, child DHWLOOPBRANCHs permitted).
RETURN Indicates a return segment (flow is only due to circulation, child DHWLOOPBRANCHs not allowed)
Units Legal Range Default Required Variability
none Yes constant

wgLength

Type: float

Length of segment.

Units Legal Range Default Required Variability
ft x \(\ge\) 0 0 No constant

wgSize

Type: float

Nominal size of pipe. CSE assumes the pipe outside diameter = size + 0.125 in.

Units Legal Range Default Required Variability
in x \(>\) 0 1 Yes constant

wgInsulK

Type: float

Pipe insulation conductivity

Units Legal Range Default Required Variability
Btuh-ft/ft2-oF x \(>\) 0 0.02167 No constant

wgInsulThk

Type: float

Pipe insulation thickness

Units Legal Range Default Required Variability
in x \(\ge\) 0 1 No constant

wgExH

Type: float

Combined radiant/convective exterior surface conductance between insulation (or pipe if no insulation) and surround.

Units Legal Range Default Required Variability
Btuh/ft2-oF x \(>\) 0 1.5 No hourly

wgExT

Type: float

Surrounding equivalent temperature.

Units Legal Range Default Required Variability
oF x \(>\) 0 70 No hourly

wgFNoDraw

Type: float

Fraction of hour when no draw occurs.

Units Legal Range Default Required Variability
oF x \(>\) 0 70 No hourly

endDHWLoopSeg

Optionally indicates the end of the DHWLOOPSEG definition.

Units Legal Range Default Required Variability
none No