DHWLOOPPUMP

DHWLOOPPUMP constructs an object representing a pump serving part a DHWLOOP. The model is identical to DHWPUMP except that that the electricity use calculation reflects wlRunF of the parent DHWLOOP.

wlpName

Optional name of pump; give after the word “DHWLOOPPUMP” if desired.

Units Legal Range Default Required Variability
63 characters none No constant

wlpMult

Type: integer

Number of identical pumps of this type. Any value \(>1\) is equivalent to repeated entry of the same DHWPUMP.

Units Legal Range Default Required Variability
x \(>\) 0 1 No constant

wlpPwr

Type: float

Pump power.

Units Legal Range Default Required Variability
W x \(>\) 0 0 No hourly

wlpLiqHeatF

Type: float

Fraction of pump power that heats circulating liquid. The remainder is discarded.

Units Legal Range Default Required Variability
0 \(\le\) x \(\le\) 1 1 No hourly

wlpElecMtr

Type: mtrName

Name of METER object, if any, to which DHWLOOPPUMP electrical energy use is recorded (under end use dhwMFL).

Units Legal Range Default Required Variability
name of a METER Parent DHWLOOP wlElecMtr No constant

endDHWLOOPPUMP

Optionally indicates the end of the DHWPUMP definition.

Units Legal Range Default Required Variability
none No constant