Skip to content

DHWLOOP

DHWLOOP constructs one or more objects representing a domestic hot water circulation loop. The actual pipe runs in the DHWLOOP are specified by any number of DHWLOOPSEGs (see below). Circulation pumps are specified by DHWLOOPPUMPs (also below).

wlName

Optional name of loop; give after the word “DHWLOOP” if desired.

Units Legal Range Default Required Variability
63 characters none No constant

wlMult

Type: integer

Number of identical loops of this type. Any value \(>1\) is equivalent to repeated entry of the same DHWLOOP (and all child objects).

Units Legal Range Default Required Variability
x \(>\) 0 1 No constant

wlFlow

Type: float

Loop flow rate (when operating).

Units Legal Range Default Required Variability
gpm x \(\ge\) 0 6 No hourly

wlTIn1

Type: float

Inlet temperature of first DHWLOOPSEG.

Units Legal Range Default Required Variability
oF x \(>\) 0 DHWSYS wsTUse No hourly

wlRunF

Type: float

Fraction of hour that loop circulation operates.

Units Legal Range Default Required Variability
x \(\ge\) 0 1 No hourly

wlFUA

Type: float

DHWLOOPSEG pipe heat loss adjustment factor. DHWLOOPSEG UA is derived (from wgSize, wgLength, wgInsulK, wgInsulThk, and wgExH) and multiplied by wlFUA. Note: does not apply to child DHWLOOPBRANCHs (see wbFUA).

Units Legal Range Default Required Variability
x \(>\) 0 1 No constant

wlLossMakeupPwr

Type: float

Specifies electrical power available to make up losses from DHWLOOPSEGs (loss from DHWLOOPBRANCHs is not included). Separate loss makeup is typically used in multi-unit HPWH systems to avoid inefficiencies associated with high condenser temperatures. Loss-makeup energy is calculated hourly and is the smaller of loop losses and wlLossMakeupPwr. The resulting electricity use (including the effect of wlLossMakeupEff) is accumulated to the METER specified by wlElecMtr (end use dhwMFL). No other effect, such as heat gain to surroundings, is modeled.

Units Legal Range Default Required Variability
W x \(\ge\) 0 0 No hourly

wlLossMakeupEff

Type: float

Specifies the efficiency of loss makeup heating if any. No effect when wlLossMakeupPwr is 0.

Units Legal Range Default Required Variability
x \(>\) 0 1 No hourly

wlElecMtr

Type: mtrName

Name of METER object, if any, to which DHWLOOP electrical energy use is recorded (under end use dhwMFL).

Units Legal Range Default Required Variability
name of a METER Parent DHWSYS wsElecMtr No constant

endDHWLoop

Optionally indicates the end of the DHWLOOP definition.

Units Legal Range Default Required Variability
none No