ACCUMULATOR

An ACCUMULATOR is driven by arbitrary subhourly expression value computed during the CSE simulation and calculates minimum, maximum, mean, and sum values for hour, day, month, and year intervals. In addition, timestamps are retained for the minimum and maximum values. ACCUMULATORs are useful for summarizing and reporting values for which there is not built-in accounting (for example, ZNRES or RSYSRES). One common use case is for reporting hour average values of internal variables that vary subhourly.

ACCUMULATORs are "observing" devices -- they have no effect on the CSE building model or calculations. ACCUMULATOR values must be reported using user-defined REPORTs or EXPORTs.

As a simple example, a report of monthly outdoor drybulb temperatures can be generated as follows --

ACCUMULATOR "ACTDB" acmValue=$tdbosh

REPORT "TODB" rpType=UDT rpFreq=Month rpTitle="Outdoor drybulb temp (F)"
  REPORTCOL colHead="Mon" colVal=$Month colWid=3
  REPORTCOL colHead="Min" colVal=@Accumulator[ "ACTDB"].M.acmMin colDec=2 colWid=6
  REPORTCOL colHead="Mean" colVal=@Accumulator[ "ACTDB"].M.acmMean colDec=2 colWid=6
  REPORTCOL colHead="Max" colVal=@Accumulator[ "ACTDB"].M.acmMax colDec=2 colWid=6
REPORT rpType=UDT rpFreq=Year rpHeader=No
  REPORTCOL colVal="Yr" colWid=3
  REPORTCOL colVal=@Accumulator[ "ACTDB"].Y.acmMin colDec=2 colWid=6
  REPORTCOL colVal=@Accumulator[ "ACTDB"].Y.acmMean colDec=2 colWid=6
  REPORTCOL colVal=@Accumulator[ "ACTDB"].Y.acmMax colDec=2 colWid=6

Resulting output --

  Outdoor drybulb temp (F)

  Mon    Min   Mean    Max
  --- ------ ------ ------
    1  28.22  46.87  60.08
    2  32.00  49.26  69.98
    3  42.08  60.79  91.40
    4  34.70  58.13  79.16
    5  44.42  67.07  97.88
    6  50.36  73.43 107.96
    7  55.04  74.02 101.48
    8  53.60  74.99 104.18
    9  48.92  69.24  97.52
   10  47.84  64.00  98.42
   11  32.54  54.47  77.00
   12  28.04  46.58  64.04

   Yr  28.04  61.65 107.96

Generalizing what is illustrated, probing @accumulator[ ].H yields statistics for the current hour, .D for the current day, .M the current month, and .Y for the year (or, more precisely, the full run, which may or may not be a full year).

A complete list of the available statistics for each interval is found in the ACCUMULATOR probe documentation.

acmName

Name of ACCUMULATOR: required for referencing in reports.

Units Legal Range Default Required Variability
63 characters none Yes constant

acmValue

Type: float

The value being accumulated. Generally expression with subhourly variability.

Units Legal Range Default Required Variability
any Yes subhourly

acmCond

Type: expression

Conditional accumulation flag. If given, accumulation occurs only when the expression value is non-0. This permits selective accumulation according to any condition that can be expressed as a CSE expression.

For example, the following would track RSYS supply cooling supply temperature when and only when the system is cooling.

ACCUMULATOR ClgTSupply acmValue=@RSYS[ 1].asSup.tDb acmCond=@RSYS[ 1].mode == 2

The acmCond prevents accumulation of values during heating or idle operation so the derived min, mean, and max values reflect only cooling.

Units Legal Range Default Required Variability
any numeric expression 1 (accumulation enabled) No subhour end of interval

endACCUMULATOR

Indicates the end of the ACCUMULATOR definition. Alternatively, the end of the definition can be indicated by the declaration of another object or by END.

Units Legal Range Default Required Variability
none No constant