6.71 zhx (owner: zone)
@zhx[1..].
Name | Input? | Runtime? | Type | Variability | Description |
---|---|---|---|---|---|
name | – | X | string | constant | – |
zhxTy | – | X | unrecognized | run start time (of each phase, autoSize or simulate) | Zhx type (cndtypes.def): lhso, lhsth, arso, arsth, arstc, or (future) nv. |
sp | – | X | number | hourly | Setpoint if heat xfer is tstat controlled (settmp), else unused (hourly variability) |
spPri | – | X | integer number | run start time (of each phase, autoSize or simulate) | Setpoint priority: low #’s used first if setpoints equal, so can eg peg air heat b4 using local heat. |
ui | – | X | integer number | run start time (of each phase, autoSize or simulate) | Terminal tu subscript if a term cap type |
zi | – | X | integer number | run start time (of each phase, autoSize or simulate) | Zone znr subscript always – for term cap or vent zhx. when stable, just use ownti? |
ai | – | X | integer number | run start time (of each phase, autoSize or simulate) | 0 or ah ss (subscript) of air handler supplying ar zhx (copied from tu). |
xiLh | – | X | integer number | run start time (of each phase, autoSize or simulate) | Subscr of local heat zhx for same terminal if any, else 0; not set for self. |
xiArH | – | X | integer number | run start time (of each phase, autoSize or simulate) | Was xiheat. subscr of air heat or air set output zhx for same terminal, if any, else 0 |
xiArC | – | X | integer number | run start time (of each phase, autoSize or simulate) | Xicool. subscr of air cool zhx for same terminal, if any, else 0 |
nxZhx4z | – | X | integer number | run start time (of each phase, autoSize or simulate) | Chain: 0 or subscript of next terminal zhx for this zone; 0?? if vent; head znr.zhx1. |
nxZhxSt4z | – | X | integer number | hourly | Chain: 0 or ss of next settmp zhx for this zone; head znr.zhx1st; kept sorted on sp/pri at runtime. |
nxZhx4a | – | X | integer number | run start time (of each phase, autoSize or simulate) | Chain: 0 or subscript of next terminal zhx for this air handler; head ah.zhx1. |
mda | – | X | integer number | hourly | For settmp, mode (mdseq[] subscr) in which this is active (ctrl’d by its sp) zhx. |