6.48 meter
@meter[1..].
Name | Input? | Runtime? | Type | Variability | Description |
---|---|---|---|---|---|
name | X | X | string | constant | – |
rate | X | X | number | input time | Cost per btu of use |
dmdRate | X | X | number | input time | Dmdcost per btu of demand, for a month |
subMtri[0] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[1] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[2] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[3] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[4] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[5] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[6] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[7] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[8] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[9] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[10] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[11] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[12] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[13] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[14] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[15] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[16] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[17] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[18] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[19] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[20] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[21] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[22] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[23] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[24] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[25] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[26] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[27] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[28] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[29] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[30] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[31] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[32] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[33] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[34] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[35] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[36] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[37] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[38] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[39] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[40] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[41] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[42] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[43] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[44] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[45] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[46] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[47] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[48] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[49] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtri[50] | X | X | integer number | run start time (of each phase, autoSize or simulate) | Submeters |
subMtrMult[0] | X | X | number | hourly | Submeter multipliers |
subMtrMult[1] | X | X | number | hourly | Submeter multipliers |
subMtrMult[2] | X | X | number | hourly | Submeter multipliers |
subMtrMult[3] | X | X | number | hourly | Submeter multipliers |
subMtrMult[4] | X | X | number | hourly | Submeter multipliers |
subMtrMult[5] | X | X | number | hourly | Submeter multipliers |
subMtrMult[6] | X | X | number | hourly | Submeter multipliers |
subMtrMult[7] | X | X | number | hourly | Submeter multipliers |
subMtrMult[8] | X | X | number | hourly | Submeter multipliers |
subMtrMult[9] | X | X | number | hourly | Submeter multipliers |
subMtrMult[10] | X | X | number | hourly | Submeter multipliers |
subMtrMult[11] | X | X | number | hourly | Submeter multipliers |
subMtrMult[12] | X | X | number | hourly | Submeter multipliers |
subMtrMult[13] | X | X | number | hourly | Submeter multipliers |
subMtrMult[14] | X | X | number | hourly | Submeter multipliers |
subMtrMult[15] | X | X | number | hourly | Submeter multipliers |
subMtrMult[16] | X | X | number | hourly | Submeter multipliers |
subMtrMult[17] | X | X | number | hourly | Submeter multipliers |
subMtrMult[18] | X | X | number | hourly | Submeter multipliers |
subMtrMult[19] | X | X | number | hourly | Submeter multipliers |
subMtrMult[20] | X | X | number | hourly | Submeter multipliers |
subMtrMult[21] | X | X | number | hourly | Submeter multipliers |
subMtrMult[22] | X | X | number | hourly | Submeter multipliers |
subMtrMult[23] | X | X | number | hourly | Submeter multipliers |
subMtrMult[24] | X | X | number | hourly | Submeter multipliers |
subMtrMult[25] | X | X | number | hourly | Submeter multipliers |
subMtrMult[26] | X | X | number | hourly | Submeter multipliers |
subMtrMult[27] | X | X | number | hourly | Submeter multipliers |
subMtrMult[28] | X | X | number | hourly | Submeter multipliers |
subMtrMult[29] | X | X | number | hourly | Submeter multipliers |
subMtrMult[30] | X | X | number | hourly | Submeter multipliers |
subMtrMult[31] | X | X | number | hourly | Submeter multipliers |
subMtrMult[32] | X | X | number | hourly | Submeter multipliers |
subMtrMult[33] | X | X | number | hourly | Submeter multipliers |
subMtrMult[34] | X | X | number | hourly | Submeter multipliers |
subMtrMult[35] | X | X | number | hourly | Submeter multipliers |
subMtrMult[36] | X | X | number | hourly | Submeter multipliers |
subMtrMult[37] | X | X | number | hourly | Submeter multipliers |
subMtrMult[38] | X | X | number | hourly | Submeter multipliers |
subMtrMult[39] | X | X | number | hourly | Submeter multipliers |
subMtrMult[40] | X | X | number | hourly | Submeter multipliers |
subMtrMult[41] | X | X | number | hourly | Submeter multipliers |
subMtrMult[42] | X | X | number | hourly | Submeter multipliers |
subMtrMult[43] | X | X | number | hourly | Submeter multipliers |
subMtrMult[44] | X | X | number | hourly | Submeter multipliers |
subMtrMult[45] | X | X | number | hourly | Submeter multipliers |
subMtrMult[46] | X | X | number | hourly | Submeter multipliers |
subMtrMult[47] | X | X | number | hourly | Submeter multipliers |
subMtrMult[48] | X | X | number | hourly | Submeter multipliers |
subMtrMult[49] | X | X | number | hourly | Submeter multipliers |
subMtrMult[50] | X | X | number | hourly | Submeter multipliers |
Y.tot | X | X | number | end of run (of each phase, autoSize or simulate) | Total of following specific end uses. code assumes precedes them. |
Y.clg | X | X | number | end of run (of each phase, autoSize or simulate) | Space cooling. code assumes 1st member. |
Y.htg | X | X | number | end of run (of each phase, autoSize or simulate) | Space heating incl heat pump compressor |
Y.hpBU | X | X | number | end of run (of each phase, autoSize or simulate) | Heat pump resistance heating (backup and defrost) |
Y.dhw | X | X | number | end of run (of each phase, autoSize or simulate) | Domestic (service) hot water heating |
Y.dhwBU | X | X | number | end of run (of each phase, autoSize or simulate) | Domestic (service) hot water backup |
Y.dhwMFL | X | X | number | end of run (of each phase, autoSize or simulate) | Domestic (service) multi-family loop energy |
Y.fanC | X | X | number | end of run (of each phase, autoSize or simulate) | Fans - cooling and cooling ventilation |
Y.fanH | X | X | number | end of run (of each phase, autoSize or simulate) | Fans - heating |
Y.fanV | X | X | number | end of run (of each phase, autoSize or simulate) | Fans - iaq ventilation |
Y.fan | X | X | number | end of run (of each phase, autoSize or simulate) | Fans - other |
Y.aux | X | X | number | end of run (of each phase, autoSize or simulate) | Hvac auxiliaries and parasitics, not including fans |
Y.proc | X | X | number | end of run (of each phase, autoSize or simulate) | Process energy |
Y.lit | X | X | number | end of run (of each phase, autoSize or simulate) | Lighting |
Y.rcp | X | X | number | end of run (of each phase, autoSize or simulate) | Receptacles |
Y.ext | X | X | number | end of run (of each phase, autoSize or simulate) | External – outdoor lights, etc |
Y.refr | X | X | number | end of run (of each phase, autoSize or simulate) | Refrigeration |
Y.dish | X | X | number | end of run (of each phase, autoSize or simulate) | Dish washing |
Y.dry | X | X | number | end of run (of each phase, autoSize or simulate) | Clothes drying |
Y.wash | X | X | number | end of run (of each phase, autoSize or simulate) | Clothes washing |
Y.cook | X | X | number | end of run (of each phase, autoSize or simulate) | Cooking |
Y.usr1 | X | X | number | end of run (of each phase, autoSize or simulate) | User-defined end use 1 |
Y.usr2 | X | X | number | end of run (of each phase, autoSize or simulate) | User-defined end use 2 |
Y.bt | X | X | number | end of run (of each phase, autoSize or simulate) | Battery output (negative) |
Y.pv | X | X | number | end of run (of each phase, autoSize or simulate) | Photovoltaic array output (negative) |
Y.allEU | X | X | number | end of run (of each phase, autoSize or simulate) | Subtotal, clg .. usr2 (= load w/o bt and pv) |
Y.cost | X | X | number | end of run (of each phase, autoSize or simulate) | Accumulated tot*rate |
Y.dmdCost | X | X | number | end of run (of each phase, autoSize or simulate) | Largest dmd*dmdrate to month level, then accumulates (mtr_accum) |
Y.dmd | X | X | number | end of run (of each phase, autoSize or simulate) | Peak use in interval; hourly value same as .tot. |
Y.dmdShoy | X | X | unrecognized | end of run (of each phase, autoSize or simulate) | Peak time as subhour of year, subhr unused: 4(hr+24jday). |
M.tot | X | X | number | end of each month | Total of following specific end uses. code assumes precedes them. |
M.clg | X | X | number | end of each month | Space cooling. code assumes 1st member. |
M.htg | X | X | number | end of each month | Space heating incl heat pump compressor |
M.hpBU | X | X | number | end of each month | Heat pump resistance heating (backup and defrost) |
M.dhw | X | X | number | end of each month | Domestic (service) hot water heating |
M.dhwBU | X | X | number | end of each month | Domestic (service) hot water backup |
M.dhwMFL | X | X | number | end of each month | Domestic (service) multi-family loop energy |
M.fanC | X | X | number | end of each month | Fans - cooling and cooling ventilation |
M.fanH | X | X | number | end of each month | Fans - heating |
M.fanV | X | X | number | end of each month | Fans - iaq ventilation |
M.fan | X | X | number | end of each month | Fans - other |
M.aux | X | X | number | end of each month | Hvac auxiliaries and parasitics, not including fans |
M.proc | X | X | number | end of each month | Process energy |
M.lit | X | X | number | end of each month | Lighting |
M.rcp | X | X | number | end of each month | Receptacles |
M.ext | X | X | number | end of each month | External – outdoor lights, etc |
M.refr | X | X | number | end of each month | Refrigeration |
M.dish | X | X | number | end of each month | Dish washing |
M.dry | X | X | number | end of each month | Clothes drying |
M.wash | X | X | number | end of each month | Clothes washing |
M.cook | X | X | number | end of each month | Cooking |
M.usr1 | X | X | number | end of each month | User-defined end use 1 |
M.usr2 | X | X | number | end of each month | User-defined end use 2 |
M.bt | X | X | number | end of each month | Battery output (negative) |
M.pv | X | X | number | end of each month | Photovoltaic array output (negative) |
M.allEU | X | X | number | end of each month | Subtotal, clg .. usr2 (= load w/o bt and pv) |
M.cost | X | X | number | end of each month | Accumulated tot*rate |
M.dmdCost | X | X | number | end of each month | Largest dmd*dmdrate to month level, then accumulates (mtr_accum) |
M.dmd | X | X | number | end of each month | Peak use in interval; hourly value same as .tot. |
M.dmdShoy | X | X | unrecognized | end of each month | Peak time as subhour of year, subhr unused: 4(hr+24jday). |
D.tot | X | X | number | end of each day | Total of following specific end uses. code assumes precedes them. |
D.clg | X | X | number | end of each day | Space cooling. code assumes 1st member. |
D.htg | X | X | number | end of each day | Space heating incl heat pump compressor |
D.hpBU | X | X | number | end of each day | Heat pump resistance heating (backup and defrost) |
D.dhw | X | X | number | end of each day | Domestic (service) hot water heating |
D.dhwBU | X | X | number | end of each day | Domestic (service) hot water backup |
D.dhwMFL | X | X | number | end of each day | Domestic (service) multi-family loop energy |
D.fanC | X | X | number | end of each day | Fans - cooling and cooling ventilation |
D.fanH | X | X | number | end of each day | Fans - heating |
D.fanV | X | X | number | end of each day | Fans - iaq ventilation |
D.fan | X | X | number | end of each day | Fans - other |
D.aux | X | X | number | end of each day | Hvac auxiliaries and parasitics, not including fans |
D.proc | X | X | number | end of each day | Process energy |
D.lit | X | X | number | end of each day | Lighting |
D.rcp | X | X | number | end of each day | Receptacles |
D.ext | X | X | number | end of each day | External – outdoor lights, etc |
D.refr | X | X | number | end of each day | Refrigeration |
D.dish | X | X | number | end of each day | Dish washing |
D.dry | X | X | number | end of each day | Clothes drying |
D.wash | X | X | number | end of each day | Clothes washing |
D.cook | X | X | number | end of each day | Cooking |
D.usr1 | X | X | number | end of each day | User-defined end use 1 |
D.usr2 | X | X | number | end of each day | User-defined end use 2 |
D.bt | X | X | number | end of each day | Battery output (negative) |
D.pv | X | X | number | end of each day | Photovoltaic array output (negative) |
D.allEU | X | X | number | end of each day | Subtotal, clg .. usr2 (= load w/o bt and pv) |
D.cost | X | X | number | end of each day | Accumulated tot*rate |
D.dmdCost | X | X | number | end of each day | Largest dmd*dmdrate to month level, then accumulates (mtr_accum) |
D.dmd | X | X | number | end of each day | Peak use in interval; hourly value same as .tot. |
D.dmdShoy | X | X | unrecognized | end of each day | Peak time as subhour of year, subhr unused: 4(hr+24jday). |
H.tot | X | X | number | end of each hour | Total of following specific end uses. code assumes precedes them. |
H.clg | X | X | number | end of each hour | Space cooling. code assumes 1st member. |
H.htg | X | X | number | end of each hour | Space heating incl heat pump compressor |
H.hpBU | X | X | number | end of each hour | Heat pump resistance heating (backup and defrost) |
H.dhw | X | X | number | end of each hour | Domestic (service) hot water heating |
H.dhwBU | X | X | number | end of each hour | Domestic (service) hot water backup |
H.dhwMFL | X | X | number | end of each hour | Domestic (service) multi-family loop energy |
H.fanC | X | X | number | end of each hour | Fans - cooling and cooling ventilation |
H.fanH | X | X | number | end of each hour | Fans - heating |
H.fanV | X | X | number | end of each hour | Fans - iaq ventilation |
H.fan | X | X | number | end of each hour | Fans - other |
H.aux | X | X | number | end of each hour | Hvac auxiliaries and parasitics, not including fans |
H.proc | X | X | number | end of each hour | Process energy |
H.lit | X | X | number | end of each hour | Lighting |
H.rcp | X | X | number | end of each hour | Receptacles |
H.ext | X | X | number | end of each hour | External – outdoor lights, etc |
H.refr | X | X | number | end of each hour | Refrigeration |
H.dish | X | X | number | end of each hour | Dish washing |
H.dry | X | X | number | end of each hour | Clothes drying |
H.wash | X | X | number | end of each hour | Clothes washing |
H.cook | X | X | number | end of each hour | Cooking |
H.usr1 | X | X | number | end of each hour | User-defined end use 1 |
H.usr2 | X | X | number | end of each hour | User-defined end use 2 |
H.bt | X | X | number | end of each hour | Battery output (negative) |
H.pv | X | X | number | end of each hour | Photovoltaic array output (negative) |
H.allEU | X | X | number | end of each hour | Subtotal, clg .. usr2 (= load w/o bt and pv) |
H.cost | X | X | number | end of each hour | Accumulated tot*rate |
H.dmdCost | X | X | number | end of each hour | Largest dmd*dmdrate to month level, then accumulates (mtr_accum) |
H.dmd | X | X | number | end of each hour | Peak use in interval; hourly value same as .tot. |
H.dmdShoy | X | X | unrecognized | end of each hour | Peak time as subhour of year, subhr unused: 4(hr+24jday). |