@doas[1..].

NameInput?Runtime?TypeVariabilityDescription
nameXXstringconstant
supFan.fanTyXXunrecognizedautosize and simulate phase start time
supFan.vfDsXXnumberend of each subhourDesign supply volumetric flow rate of the heat exchanger
supFan.vfDs_AsXXnumberautosize and simulate phase start time
supFan.vfDs_AsNovXXnumberautosize and simulate phase start time
supFan.vfMxFXXnumberautosize and simulate phase start time
supFan.pressXXnumberrun start time (of each phase, autoSize or simulate)
supFan.effXXnumberrun start time (of each phase, autoSize or simulate)
supFan.shaftPwrXXnumberrun start time (of each phase, autoSize or simulate)
supFan.elecPwrXXnumberrun start time (of each phase, autoSize or simulate)
supFan.motTyXXunrecognizedrun start time (of each phase, autoSize or simulate)
supFan.motEffXXnumberautosize and simulate phase start time
supFan.motPosXXunrecognizedautosize and simulate phase start time
supFan.curvePy.k[0]XXnumberautosize and simulate phase start time
supFan.curvePy.k[1]XXnumberautosize and simulate phase start time
supFan.curvePy.k[2]XXnumberautosize and simulate phase start time
supFan.curvePy.k[3]XXnumberautosize and simulate phase start time
supFan.curvePy.k[4]XXnumberautosize and simulate phase start time
supFan.curvePy.k[5]XXnumberautosize and simulate phase start time
supFan.mtriXXinteger numberinput time
supFan.endUseXXinteger numberautosize and simulate phase start time
supFan.auszXXinteger numberrun start time (of each phase, autoSize or simulate)
supFan.outPowerXXnumbersubhourly
supFan.airPowerXXnumbersubhourly
supFan.cMxXXnumberend of each subhour
supFan.cXXnumberend of each subhour
supFan.tXXnumberend of each subhour
supFan.frOnXXnumberend of each subhour
supFan.pXXnumberend of each subhour
supFan.qXXnumberend of each subhour
supFan.dTXXnumberend of each subhour
supFan.qAroundXXnumberend of each subhour
exhFan.fanTyXXunrecognizedautosize and simulate phase start time
exhFan.vfDsXXnumberend of each subhourDesign supply volumetric flow rate of the heat exchanger
exhFan.vfDs_AsXXnumberautosize and simulate phase start time
exhFan.vfDs_AsNovXXnumberautosize and simulate phase start time
exhFan.vfMxFXXnumberautosize and simulate phase start time
exhFan.pressXXnumberrun start time (of each phase, autoSize or simulate)
exhFan.effXXnumberrun start time (of each phase, autoSize or simulate)
exhFan.shaftPwrXXnumberrun start time (of each phase, autoSize or simulate)
exhFan.elecPwrXXnumberrun start time (of each phase, autoSize or simulate)
exhFan.motTyXXunrecognizedrun start time (of each phase, autoSize or simulate)
exhFan.motEffXXnumberautosize and simulate phase start time
exhFan.motPosXXunrecognizedautosize and simulate phase start time
exhFan.curvePy.k[0]XXnumberautosize and simulate phase start time
exhFan.curvePy.k[1]XXnumberautosize and simulate phase start time
exhFan.curvePy.k[2]XXnumberautosize and simulate phase start time
exhFan.curvePy.k[3]XXnumberautosize and simulate phase start time
exhFan.curvePy.k[4]XXnumberautosize and simulate phase start time
exhFan.curvePy.k[5]XXnumberautosize and simulate phase start time
exhFan.mtriXXinteger numberinput time
exhFan.endUseXXinteger numberautosize and simulate phase start time
exhFan.auszXXinteger numberrun start time (of each phase, autoSize or simulate)
exhFan.outPowerXXnumbersubhourly
exhFan.airPowerXXnumbersubhourly
exhFan.cMxXXnumberend of each subhour
exhFan.cXXnumberend of each subhour
exhFan.tXXnumberend of each subhour
exhFan.frOnXXnumberend of each subhour
exhFan.pXXnumberend of each subhour
exhFan.qXXnumberend of each subhour
exhFan.dTXXnumberend of each subhour
exhFan.qAroundXXnumberend of each subhour
supTHXXnumbersubhourlySupply temperature heating setpoint
EIRHXXnumbersubhourlyHeating coil energy input ratio (1/efficiency (or 1/cop)
coilHMtriXXinteger numberinput timeMeter for heating coil
supTCXXnumbersubhourlySupply temperature cooling setpoint
EIRCXXnumbersubhourlyCooling coil energy input ratio (1/efficiency (or 1/cop)
SHRtargetXXnumbersubhourlyTarget cooling coil shr. could be overriden by oa_shr.
coilCMtriXXinteger numberinput timeMeter for heating coil
loadMtriXXinteger numberinput timeLoadmtr idx for accumulation of coil output
tExXXnumbersubhourlyDoas exterior air drybulb temp, f
wExXXnumbersubhourlyDoas exterior air humidity ratio, lb/lb
hx.VfDsXXnumberrun start time (of each phase, autoSize or simulate)Design supply volumetric flow rate of the heat exchanger
hx.f2XXnumberrun start time (of each phase, autoSize or simulate)Flow fraction for second set of inputs (default 0.75)
hx.senEffH[0]XXnumberrun start time (of each phase, autoSize or simulate)Heat exchanger heating sensible effectiveness
hx.senEffH[1]XXnumberrun start time (of each phase, autoSize or simulate)Heat exchanger heating sensible effectiveness
hx.latEffH[0]XXnumberrun start time (of each phase, autoSize or simulate)Heat exchanger heating latent effectiveness
hx.latEffH[1]XXnumberrun start time (of each phase, autoSize or simulate)Heat exchanger heating latent effectiveness
hx.senEffC[0]XXnumberrun start time (of each phase, autoSize or simulate)Heat exchanger cooling sensible effectiveness
hx.senEffC[1]XXnumberrun start time (of each phase, autoSize or simulate)Heat exchanger cooling sensible effectiveness
hx.latEffC[0]XXnumberrun start time (of each phase, autoSize or simulate)Heat exchanger cooling latent effectiveness
hx.latEffC[1]XXnumberrun start time (of each phase, autoSize or simulate)Heat exchanger cooling latent effectiveness
hx.bypassXXinteger numberrun start time (of each phase, autoSize or simulate)Hx can be bypassed when not adventatgeous
hx.auxPwrXXnumbersubhourlyAuxiliary power, w
hx.auxMtriXXinteger numberrun start time (of each phase, autoSize or simulate)Meter for auxiliary power
hx.supInAF.tdbXXnumberend of each subhour
hx.supInAF.wXXnumberend of each subhour
hx.supInAF.amfXXnumberend of each subhour
hx.hxInAF.tdbXXnumberend of each subhour
hx.hxInAF.wXXnumberend of each subhour
hx.hxInAF.amfXXnumberend of each subhour
hx.hxOutAF.tdbXXnumberend of each subhour
hx.hxOutAF.wXXnumberend of each subhour
hx.hxOutAF.amfXXnumberend of each subhour
hx.bypassAF.tdbXXnumberend of each subhour
hx.bypassAF.wXXnumberend of each subhour
hx.bypassAF.amfXXnumberend of each subhour
hx.exhInAF.tdbXXnumberend of each subhour
hx.exhInAF.wXXnumberend of each subhour
hx.exhInAF.amfXXnumberend of each subhour
hx.supOutAF.tdbXXnumberend of each subhour
hx.supOutAF.wXXnumberend of each subhour
hx.supOutAF.amfXXnumberend of each subhour
hx.bypassFracXXnumberend of each subhourFraction of supply inlet air bypassing heat exchanger
hx.tSetXXnumberend of each subhourSetpoint temperature for air exiting heat exchanger
hx.sensEffXXnumberend of each subhourSensible efficacy
hx.latEffXXnumberend of each subhourLatent efficacy
supAF.tdbXXnumberend of each subhour
supAF.wXXnumberend of each subhour
supAF.amfXXnumberend of each subhour
exhAF.tdbXXnumberend of each subhour
exhAF.wXXnumberend of each subhour
exhAF.amfXXnumberend of each subhour
supQSenXXnumberend of each subhourSensible heat added (+) or removed (-) from the supply for tempering
supQLatXXnumberend of each subhourLatent heat added (+) or removed (-) from the supply for tempering
SHRXXnumberend of each subhourActual cooling coil shr. same as oa_shrtarget unless adjusted for humidity limits.