6.13 DHWLoop (owner: DHWSYS)
@DHWLoop[1..].
Name | Input? | Runtime? | Type | Variability | Description |
---|---|---|---|---|---|
name | X | X | string | constant | – |
mult | X | X | integer number | input time | Multiplier: number of identical loops |
wlpCount | X | X | integer number | run start time (of each phase, autoSize or simulate) | Total # of child dhwlooppumps |
flow | X | X | number | hourly | Current loop recirculation max flow, gpm |
runF | X | X | number | hourly | Current hour recirculation operation fraction |
tIn1 | X | X | number | hourly | Entering temperature at 1st dhwloopseg |
fUA | X | X | number | input time | Ua adjustment factor for child dhwloopsegs |
lossMakeupPwr | X | X | number | hourly | Loss makeup heating (electrical) power, w |
lossMakeupEff | X | X | number | hourly | Loss makeup heating efficiency |
elecMtri | X | X | integer number | input time | Meter for loop electricity use (default = parent ws_elecmtri) |
segTotals.count | X | X | number | run start time (of each phase, autoSize or simulate) | – |
segTotals.len | X | X | number | run start time (of each phase, autoSize or simulate) | – |
segTotals.vol | X | X | number | run start time (of each phase, autoSize or simulate) | – |
segTotals.exArea | X | X | number | run start time (of each phase, autoSize or simulate) | – |
segTotals.UA | X | X | number | run start time (of each phase, autoSize or simulate) | – |
branchTotals.count | X | X | number | run start time (of each phase, autoSize or simulate) | – |
branchTotals.len | X | X | number | run start time (of each phase, autoSize or simulate) | – |
branchTotals.vol | X | X | number | run start time (of each phase, autoSize or simulate) | – |
branchTotals.exArea | X | X | number | run start time (of each phase, autoSize or simulate) | – |
branchTotals.UA | X | X | number | run start time (of each phase, autoSize or simulate) | – |
volRL | X | X | number | end of each hour | Current hour volume returned to water heater, gal |
qLiqLP | X | X | number | end of each hour | Heat added to liquid by dhwlooppump(s), btu |
HRLL | X | X | number | end of each hour | Current hour loop seg pipe losses, btu |
HRLLnet | X | X | number | end of each hour | Wl_hrll adjusted for pump by pump heat and |
HRBL | X | X | number | end of each hour | Current hour branch pipe loss, btu |
t24WL | X | X | number | end of each hour | Current hour branch waste loss volume, gal |
tRL | X | X | number | end of each hour | Current hour average return temp, f |